LSPEC 160 radon meter

LSPEC 160 radon measuring instrument is a continuous radon measuring instrument, which uses static electricity to collect radon decay daughters for cumulative measurement. It has high sensitivity, small volume and convenient operation to obtain results on site. It can be used for indoor radon measurement, radon measurement in soil, radon measurement in aqueous solution and other fields.

LSPEC 160 radon meter is a new type of radon measuring instrument that can continuously measure radon. It uses static electricity to collect radon decay daughters for cumulative measurement, with high sensitivity, small volume and convenient operation. It can be used for indoor radon measurement, radon measurement in soil, radon measurement in aqueous solution and other fields.

 

System configuration:

1. One radon and thorium analyzer host;

2. 1 portable instrument box;

3. 1 power adapter;

4. 1 data connection line;

5. 1 set of data analysis and storage equipment;

6. Two 5m long terminal blocks.








       Using semiconductor α Particle detector, by detecting each α The energy of particles to identify the α Particles can be clearly displayed α Spectrum. The sampling chamber is 1.2L, the inner surface is conductive, and the top center is a α For particle detector, positive high pressure is added between the conductive layer and the detector, and an electric field is formed in the internal space to push positively charged particles towards the detector. After the decay of radon - 222, polonium-218 with positive charge is formed, which adheres to the detector under the action of internal electric field. When Polonium-218 with a half-life of 3.05 minutes decays on the detector surface, its α The particles enter the detector and form α An electrical signal that is proportional to the energy of a particle. Different isotope formation α The energy of particles is different, resulting in different intensity spectrum peaks.



Detector

α semiconductor detector

Barometric correction

The measured value can be automatically corrected according to the atmospheric pressure

Measuring method

Electrostatic collection energy spectrum method to avoid pollution

Long term working humidity

Below 95% RH (non condensing)

Measuring period

Multiple options

Power supply mode

Power adapter with rear battery

Internal storage

No less than 5000 pieces of complete measurement result data can be produced, including energy spectrum data, which can be circularly covered

Battery duration

6h

Sensitivity

0.8cph/Bqm-3

Data analysis and storage device technical parameters

15.6 inch, I9-10885H, 32GB running memory, 2TB memory, 4K touch screen, 4GB single display, pre installed genuine Chinese version of windows10, pre installed genuine office or wps office software, and provided genuine code of system and application software.

Lower detection limit

10Bqm-3

Language

Chinese display

Flow

Self stable crossflow


Acceptance: The acceptance shall be completed within 3 months after the contract takes effect. The technicians authorized by the instrument manufacturer shall unpack, install and debug the instrument at the user's site, and cooperate with the user for acceptance. The instrument shall not be officially delivered to the user until the technical indicators of the instrument are accepted and qualified, an acceptance report is issued, and the user agrees to sign.

Warranty: After the installation and acceptance of the equipment, the instrument manufacturer is required to provide a one-year free warranty service for the whole set of equipment, with lifelong maintenance.


Application scenario:

1. Radium in drinking water, mineral water and total α determination;

2. Detection of radon concentration in engineering foundation soil;

3. Quality inspection, construction, environmental geology and earthquake;

4. Determination of radon concentration in public health environment;

5. Indoor and outdoor ambient air radon concentration detection;

6. Prediction and monitoring of earthquake and geological disasters;


LSPEC 160 radon meter
LSPEC 160 radon measuring instrument is a continuous radon measuring instrument, which uses static electricity to collect radon decay daughters for cumulative measurement. It has high sensitivity, small volume and convenient operation to obtain results on site. It can be used for indoor radon measurement, radon measurement in soil, radon measurement in aqueous solution and other fields.
Long press to look detail
Long by picture save/share
INQUIRY

在线询盘 MORE+
  • 联系人 *

  • 手机 *

  • 描述

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

enquiry content:


You have no items to require

Add Successfully

LSPEC 160 radon meter

enquiry
INQUIRY

在线询盘 MORE+
  • 联系人 *

  • 手机 *

  • 描述

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

enquiry content:


You have no items to require

Add Successfully

TEL: +86 15565213902 

Email: lsgdjs@lsgdjs.cn

Location: No. 55 Yulan Street, High-tech Industrial Cluster, Zhengzhou City, China

Website: www.lspec.com.cn

© 2020 deome site . All rights reserved       Site Map

TEL: +86 15565213902 

Email: lsgdjs@lsgdjs.cn

Location: No. 55 Yulan Street, High-tech Industrial Cluster, Zhengzhou City, China

Website: www.lspec.com.cn

© 2020  All rights reserved Raytheon        Site Map

添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了